RE-Y(St)Y-PIMF

RE-Y(St)Y-PIMF

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1MULTİ-PAİR, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: White / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 1 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
DD-Lötsteckverbinder

DD-Lötsteckverbinder

DD Kabelkonfektion – wir schaffen beste Verbindungen
Kabel- und -durchführungen von CONEC

Kabel- und -durchführungen von CONEC

Durch die Verwendung von Conec-Wanddurchführungen mit rückseitig angeschlossenen Kabeln ist es möglich, Daten über M8x1- oder M12x1-Steckverbinder ins Innere von Schaltschränken oder Geräten zu verteilen.
Datenkabel HARTING

Datenkabel HARTING

Die Datenkabel von HARTING sind speziell für die robusten Anforderungen im industriellen Umfeld konzipiert. In Kombination mit den HARTING Steckverbindern unterstützen diese Kabel Fast Ethernet, Gigabit Ethernet, 10 Gbit Ethernet und Single Pair Ethernet (SPE). Sie sind vollgeschirmt und für Bandbreiten von 100 MHz (Kategorie 5/5e) bis hin zu 1000 MHz (Kategorie 7A) ausgelegt. Die Architektur der Verkabelung ist so gestaltet, dass eine einfache, schnelle und sichere Installation vor Ort gewährleistet ist. Hybride Kabellösungen, die sowohl Datenübertragung als auch Stromversorgung in einem Kabel vereinen, runden das Portfolio ab und sind perfekt für Plug & Play-Lösungen geeignet.
XBK-INDUSTRY - KUNSTSTOFF-INDUSTRIELEITUNGEN - Schlauchleitungen

XBK-INDUSTRY - KUNSTSTOFF-INDUSTRIELEITUNGEN - Schlauchleitungen

PVC-Schlauchleitungen H03VVF, H05VV-F Flache PVC-Schlauchleitungen H03VVH2-F, H05VVH2-F Wärmebeständige Schlauchleitungen H03V2V2-F, H05V2V2-F Halogenfreie Schlauchleitungen H03Z1Z1-F, H05Z1Z1-F
BWU3534 | Aktiver Verteiler AS-i, IP67

BWU3534 | Aktiver Verteiler AS-i, IP67

Aktiver Verteiler AS-i, IP67, Gehäuse 35 mm tief, 1 digitaler Eingang, 4 digitale Ausgänge, Eingangsspannung/Sensorversorgung aus AS-i, Ausgangsspannung/Aktuatorversorgung aus AS-i, Peripherieanschluss über 1 x M12-Kabelbuchse, gerade, 5-polig und 1 x M12-Kabelbuchse, gewinkelt, 5-polig, Kabellänge 0,3 m, flache Bauform, Montage in Kabelkanal möglich (Einbautiefe > 35 mm), LED Statusanzeige, Anschlüsse für 1 x AS-i Profilkabel, AS-i Anschluss über Profilkabel und Durchdringungstechnik, 1 AB Slave
RE-2Y(St)H & RE-2X(St)H MP

RE-2Y(St)H & RE-2X(St)H MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black cores numbered 1-2-3…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2
RE-2Y(St)H&RE-2X(St)H-MP

RE-2Y(St)H&RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Pairs laid up in layers of optimum pitch Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)H & RE-2X(St)H-MP

RE-2Y(St)H & RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4
Crimp-Schliffbildanalyse

Crimp-Schliffbildanalyse

Qualitätsüberprüfung Ihrer crimps Im Schliffbildlabor werden mittels Schliffbild und Auswertungssoftware Dokumentationen erstellt um die Einwand freie Vercrimpung der angebrachten Kontakte zu bewerten
RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl MP

RE-2Y(St)YSWAY-fl & RE-2X(St)YSWAY-fl MP

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Inner sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF

RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / Blue / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF

RE-2Y(St)H-TIMF&RE-2X(St)H-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H-PIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2 Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2
RE-2G(St)HSWAH-CI  FE180

RE-2G(St)HSWAH-CI FE180

HALOGEN-FREE FIRE RESISTANT (Cl) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, SILICONE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF

RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (2Y): PVC compound, EN 50290-2-22 Inner sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2G(St)H-CI  FE180 MP

RE-2G(St)H-CI FE180 MP

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP

RE-Y(St)Y-fl & RE-Yw(St)Yw-fl MP

INSTRUMENTATION CABLES, EN 50288-7SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)Yw cables are suitable. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP

RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-Y(St)YSWAY-PIMF

RE-Y(St)YSWAY-PIMF

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 2MULTİ-PAİR, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: White / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Flame retardance test: IEC 60332-1 & BS EN 60332-1 Min. bending radius: 6 x D
RE-2G(St)H-CI  FE180

RE-2G(St)H-CI FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ
RE-2Y(St)2YSWAY-fl-MP

RE-2Y(St)2YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 2SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1-1, 2-2-2,… Pair: Two conductors twisted to a pair Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,0 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,5 mm2 : max. 120 pF/m (≤2 pairs),max. 85 pF/m (all other pairs) Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1